Sean Moran, our Principal Engineer writes this occasional blog about his experiences. Our company (Expertise Limited) design, commission and troubleshoot Sewage, Industrial Effluent and Water Treatment Plant. We provide Process and Hydraulic Design, Staff Training, Review and Audit and Expert Witness Services.

Wednesday, 4 June 2008

 

Design Errors: Static Mixers

A quiet sort of a week in the main. Cyril continues his research into treatment of PCBs in groundwater. I have been engaged with the pharmaceutical client mentioned previously on here.

They have what must be one of the worst effluent treatment plants I have ever seen in terms of fundamental design flaws. One of the biggest of them was the use of static mixers to mix acid and coagulant with effluent, which was pumped by diaphragm pumps. This showed a fundamental misunderstanding of the nature of static mixers in the system designer. Static mixers blend fluids across the body of the mixer. If you feed them with a pulsating flow from a diaphragm pump, and an out-of synch. pulsating flow from a dosing pump, you end up with constantly varying degrees of mix in the outlet flow. The normal rule of sampling at least 10 pipe diameters downstream to get 95% degree of mix no longer applies. Your pH probe for example will see extreme variation in measures pH, and instead of gaining control to +/- 0.1pH units as you should from a system like this, you will be lucky to see +/- 0.5 pH units.

Labels: , , , , , , , , , , ,


Archives

May 2008   June 2008   July 2008   August 2008   September 2008   October 2008   December 2008   February 2009   March 2009   April 2009   May 2009   June 2009   July 2009   August 2009   September 2009   October 2009   November 2009   December 2009   January 2010   February 2010   March 2010  

This page is powered by Blogger. Isn't yours?

Subscribe to Posts [Atom]